Dry cooler is a device for cooling water or glycol using atmospheric air — without water consumption, without medium evaporation, and without the risk of system contamination. We manufacture dry coolers with cooling capacities ranging from 5 kW to 1760 kW, featuring electric or hydraulic drives, available in single-station and multi-section configurations — tailored to the specific requirements of any industrial installation or server room.
© AS-TECHNIK NOWA Sp. z o.o. – 3D model protected by copyright; downloading, copying, and use without the owner’s consent is prohibited.
Dry cooler as a standalone cooling system for chilled water or glycol in server rooms — in the Polish and Central European climate, atmospheric air is cool enough for a significant part of the year to handle cooling without chillers. Real reduction in energy consumption with zero water usage and full compliance with the growing environmental requirements imposed on data centers.
Heat dissipation from cooling systems of compressors, generators, transformers, and other industrial equipment generating large amounts of heat continuously — without water infrastructure and without permanent maintenance of a water treatment system.
Dry coolers for liquid cooling in CHP systems, biogas plants, and power stations — where cooling reliability is a prerequisite for energy production continuity, and access to cooling water is limited or restricted by regulations.
Liquid cooling in CHP systems, biogas plants, and power generators — operating continuously for thousands of hours with minimal maintenance.
Dry coolers for free cooling of server rooms and data centers — zero water consumption, closed loop, ability to operate without chillers for most of the year in temperate climates. Capacities from several tens to 1760 kW allow servicing both small server rooms and large colocation facilities.
Dry coolers for cooling chilled water and glycol in manufacturing plants — as an alternative to cooling towers where process water consumption is undesirable or impossible.
Dry coolers for machinery and equipment operating in harsh environmental conditions — available in versions adapted for dusty and chemically aggressive areas, including ATEX zones.
Cooling towers and wet cooling systems require constant access to make-up water, a water treatment system, and regular maintenance against scale and corrosion. A dry cooler eliminates these requirements entirely — the sole cooling medium is atmospheric air, and the process medium circulates in a sealed, closed loop. In the Polish climate, this is a particular advantage for data centers and server rooms: for a significant part of the year, the outdoor temperature allows for full cooling without chillers — so-called free cooling. This brings direct energy savings while simultaneously meeting the growing environmental requirements regarding water consumption by data centers. We manufacture dry coolers with capacities from 5 kW to 1760 kW — each as an individual project, not a catalog product.